SPECTRORADIOMETER

(Already installed in a Therapeutic Contract Research  company)

 

 

LED Measurement

Display  Measurement
Spectral Measurement
Accuracy and Reliability

 

 

Technical specifications

 

 

Model

UV/VIS

UV/VIS/NIR

VIS

VIS/NIR

NIR

IR1

IR2

 

Spectral range

 

200-800 nm

220-1020 /

300-1100 nm

 

360-830 nm

 

380-1040 nm

 

750-1050 nm

 

780-1650 nm

 

1500-2150 nm

Detector

BT-CCD

BT-CCD

BT-CCD

BT-CCD

BT-CCD

InGaAs

ext. InGaAs

Number of pixels

1024 x 128

1024 x 128

1024 x 128

1024 x 128

1024 x 128

512

256

Spectral resolution *1

2.7 nm

3.7 nm

2.2 nm

3.0 nm

2.0 nm

9 nm

15 nm

Data point interval

0.6 nm

0.8 nm

0.5 nm

0.65 nm

0.3 nm

2.1 nm

3 nm

Wavelength accuracy

+/-0.3 nm

+/-0.3 nm

+/-0.3 nm

+/-0.3 nm

+/-0.3 nm

+/-0.5 nm

+/-1.5 nm

Stray light (broadband for Illuminant A) *2

 

5·10E-4

 

5·10E-4

 

5·10E-4

 

5·10E-4

 

5·10E-4

 

1·10E-3

 

1·10E-3

Stray light for LEDs *3

1·10E-4

1·10E-4

1·10E-4

1·10E-4

1·10E-4

1·10E-3

-

 

Integration time

10 msec -

65 sec

10 msec -

65 sec

10 msec -

65 sec

10 msec -

65 sec

10 msec -

65 sec

10 msec -

65 sec *8

10 msec -

200 msec

Linearity

0.5%

0.5%

0.5%

0.5%

0.5%

1%

1%

Cooling

-10°C

-10°C

-10°C

-10°C

-10°C

-10°C

-20°C

Spectroradiometry

 

Irradiance sensitivity range *4

 

5·10E-8 500

W/m2nm

 

2·10E-8 200

W/m2nm

 

3·10E-8 300

W/m2nm

 

2·10E-8 200

W/m2nm

 

5·10E-8 500

W/m2nm

3·10E-6

3·10E+4 W/

m2nm

 

3·10E-5 0.6

W/m2nm

Signal sensitivity at 1s integ- ration time *4

1·10E-6 W/

m2nm

4·10E-7 W/

m2nm

6·10E-7 W/

m2nm

4·10E-7 W/

m2nm

1·10E-6 W/

m2nm

2·10E-4 W/

m2nm

3·10E-4 W/

m2nm

Spectroradiometric accuracy *5

 

+/-3.5%

 

+/-3.5%

 

+/-3.5%

 

+/-3.5%

 

+/-3.5%

 

+/-5%

 

+/-8%

Spectrophotometry

 

Baseline noise *6

 

+/-60 counts, or +/-0.4%

+/-25 counts or +/-0.2%

Transmission measuring accuracy

 

+/-0.5% T or +/-0.02A at 1A

+/-1% T or

+/- 0.05A at 1A

Baseline drift *7

0.15%/h or +/- 0.006A/h

0.15%/h or +/- 0.006 A/h

Spectrograph

Focal length, grating

Approx. 120 mm f/3.5 / plane ruled grating

Slit

Standard: 100 μm, optional 50 μm or 250 μm; 250 μm standard at IR2

Filter wheel

Density filter OD 1 to OD 4; UV/VIS and UV/VIS/NIR with UV density filters

Electrical data

AD converter

15 Bit resolution

PC interface

USB 2.0 standard; optional: PCI bus plug-in card in place of USB 2.0

Triggering

1 TTL input with an ascending slope; 2 software-controlled TTL outputs; 1 TTL output with flash pulse

Other

Dimensions (H, W, D)

192 x 330 x 348 mm3

Power consumption

50 VA max.

Ambient temperature

15 - 35°C; relative humidity 0 - 70%, non-condensing

Weight

Approx. 10 kg

Applicable standards

Meets EN 60721-4-7 Class 7M2, EN 60721-4-7 Class 2M2, EN 61326:2004-05 and EN 61010-2002-08

 

Southern Dynamics (P) Ltd,
New #37, (Old #110), 4th Floor, Nelson Manickam Road, Chennai 600 029. India
Tel: 91-44-2374 1203 Fax: 91-44-4211 3813
Email: sales@southerndynamics.com, southerndynams@gmail.com
www.southerndynamics.com

.

Updated 14th April 2017 ©2017  Southern Dynamics (P) Ltd Webmaster