ULTRASONIC ANEMOMETER
Output
quantities
Anemometric
Wind
speed
and
direction,
U-V-W
components,
sound
speed,
sonic
temperature
Meteorological
Pressure,
Temperature,
Relative
Humidity
Heading
Compass
with
magnetic
azimuth
Ø
Ø |
Wind
Speed
Unit
Range
Resolution
Accuracy
Wind
Direction |
m/s,
cm/s,
km/h,
knots,
mph 0 ÷ 70
m/s
(252
km/h)
0.01
m/s
± 1%
of
reading |
|
Range |
Azimuth:
0
÷
360°
Elevation:
±
60° |
|
Resolution |
0.1
° |
|
Accuracy |
±
1
° |
Ø |
Sound
Speed |
|
|
Range |
300
÷
380
m/s |
|
Resolution |
0.01
m/s |
|
Accuracy |
± 1%
of
reading |
Ø
Sonic
Temperature |
|
Range |
-40
+60°C |
|
Resolution |
0.1
°C |
|
Accuracy |
±
1
°C |
Ø |
Compass |
|
|
Range |
0÷3600
/10° |
|
Resolution |
0.1° |
|
Accuracy |
±
1° |
Ø |
Moving
Averages |
1÷60
sec
/
1÷60
min |
Ø |
Ultrasonic
rate |
60Hz |
Digital
Outputs
Ø
Quantities
Anemometric
and
compass.
Pressure,
Temperature, Relative
Humidity
Ø
Communications
RS232 and
RS422 full duplex,
RS485
Multidrop
and
AoXnd
half
duplex
Ø
Baud
rate 9600 ÷ 115200
bit/sec
Ø
Output
Rate Normal
mode
(Slow):
1
÷ 3600
sec
Digital
High
Frequency
(Fast)
:
fixed
50Hz
Analog
Outputs
Ø
Quantities
5 to be
selected from
output
quantities
(anemometric,
compass,
meteo).
Ø
Range
0-20mA,
4-20mA,
0÷1V,
0÷5V,
0÷10V,
1÷5V
Ø
Resolution
14 bits
max
Analog Outputs
Extended
(With ICP
DAS
I-7024®
module
On
request
when
placing
the
order)
Power
Supply
Ø
Range
12 ÷ 30
Vdc
Ø
Power
< 2W (Typically:
110mA
@
15Vdc)
< 6W
Models
with
heaters and
environment
temperature
not
lower
than
–10
°C
Heaters
Option
(On
request
when
placing
the
order).
Heating
with
automatic
temperature
control
on sonic transducers,
to prevent
ice and
snow
formation
and
ensure
a correct functioning
even
when
sleeting
or
snowing.
RS422
Option
(On
request
when
placing
the
order).
Integrated
circuit
for
communication RS422
4-wire
full
duplex.
Weight |
Environmental
Conditions |
|
Temperature
Range |
-40 +60°C |
~ |
EMC |
CE
Regulations |
|
Precipitation |
Operation
ensured
up
to 300mm/hr of
water |
|
Humidity |
0%
÷
100%
RH |
1.6
PRESSURE
- TEMPERATURE
– RELATIVE
HUMIDITY
SENSORS
Pressure.
Piezo
resistive
Sensor.
Analog
Output:
0-20mA,
4-20mA,
0÷1V,
0÷5V,
0÷10V, 1÷5V
Analog
Output
Extended
(AoXnd):
0-20mA,
4-20mA,
0÷5V,
0÷10V Range:
600 ÷
1100 mbar
Resolution:
0.1
mbar
Accuracy:
±
0.4 mbar
@ 20
°C
Temperature
Effects:
±
0.8mbar
between
–40°C
and
+60°C Long-term
stability:
1mbar
in
6 months
@ 20
°C
Temperature.
Sensor:
Pt100
Analog
Output:
0-20
mA,
4-20
mA,
0÷1V,
0÷5V,
0÷10V,
1÷5V
Analog
Output
Extended
(AoXnd):
0-20mA,
4-20mA,
0÷5V,
0÷10V Range
: –40
+ 60
°C
Resolution:
0.1 °C
Accuracy:
± 0.2
°C,
±
0.15%
of
reading
Relative
Humidity.
Capacity
sensor:
H6100
Analog
Output
(0
%÷100
%
RH):
0-20mA,
4-20mA,
0÷1V,
0÷5V,
0÷10V,
1÷5V
Analog
Output
Extended
(AoXnd):
0-20mA,
4-20mA,
0÷5V,
0÷10V Range:
5÷98%
RH
Resolution:
0.1 %
Accuracy:
± 2.5%
RH @